siFramo 100
Square Coupling PK F 100 4kt HCP




Application
Internal splice connecting element for TP F 100 Beam Section, particularly suitable for vertical extension. Should the component be used for horizontal application, the bending moment needs to be considered.
Installation
To be fastened with 2 x 4 FLS F Self Forming Screws. For optimal bending moment, distance between screws to be as far from each other as possible.
Note:
Self Forming Screw FLS F to be fastened on two sides with a distance of minimum of 100mm and to be fastened symmetrically.
To optimise the bending moment the FLS F should be installed to maintain the pipe weight of the effective flow - i.e. screws are located top and bottom for horizontal cross bars not sideways.
Technical Data
Type | L [mm] | H [mm] | B [mm] | Fmax [kN] | Mbmax [kNm] |
---|---|---|---|---|---|
PK F 100 4kt | 442.5 | 90 | 90 | 10.0 | 0.5 |
Material: | Steel, HCP |